						Technical specification
					 | 
				
				
					| 
						Frequency
					 | 
					
						 
					 | 
				
				
					| 
						Frequency Range
					 | 
					
						10MHz to 6000MHz
					 | 
				
				
					| 
						Setting Resolution
					 | 
					
						10Hz by direct keyboard entry, or in user-set increments of 10Hz to 999?999MHz by rotary control or increment–decrement keys
					 | 
				
				
					| 
						Phase Noise
					 | 
					
						500MHz Carrier: <-110dBc/Hz @ 20kHz offset; <-120dBc/Hz @ 100kHz
					 | 
				
				
					| 
						 
					 | 
					
						3GHz Carrier: <-95dBc/Hz @ 20kHz offset; <-110dBc/Hz @ 100kHz offset
					 | 
				
				
					| 
						 
					 | 
					
						6GHz Carrier: <-89dBc/Hz @ 20kHz offset; <-104dBc/Hz @ 100kHz offset
					 | 
				
				
					| 
						Residual FM
					 | 
					
						Equivalent peak deviation for 300Hz to 3.4kHz B/W: 12Hz at 500MHz carrier
					 | 
				
				
					| 
						Settling Time
					 | 
					
						<8ms to settle within 100Hz or 0.1ppm of final frequency, if greater
					 | 
				
				
					| 
						Reference Frequency
					 | 
					
						Internal or External (via rear panel BNC)
					 | 
				
				
					| 
						Internal Accuracy
					 | 
					
						+/- 1 ppm over 15°C to 30°C; +/- 2 ppm over 5°C to 40°C
					 | 
				
				
					| 
						Internal Stability
					 | 
					
						< +/-1ppm/year ageing
					 | 
				
				
					| 
						Internal Ref. Out
					 | 
					
						10MHz from 50 Ohms, amplitude 2V pk-pk into 50 Ohms
					 | 
				
				
					| 
						External Ref In
					 | 
					
						10MHz into 50 Ohms, amplitude 2V pk-pk to 5V pk-pk
					 | 
				
				
					| 
						Output Level
					 | 
					
						 
					 | 
				
				
					| 
						Level Range
					 | 
					
						–110dBm to +7dBm (0.1μV to 500mV into 50 Ohms)
					 | 
				
				
					| 
						Setting Resolution
					 | 
					
						0.1dB (or 0.01μV to 1mV) by direct keyboard entry, or in user-set increments of 0.1dB to 100dB (or 0.01μV to 100mV)
					 | 
				
				
					| 
						Accuracy
					 | 
					
						Better than ± 2dBm
					 | 
				
				
					| 
						Harmonics
					 | 
					
						<-25dBc at +7dBm. <-30dBc@levels <=0dBm 30 to 6000MHz, <-25dBc@levels <=0dBm 10 to 30MHz
					 | 
				
				
					| 
						Sub-Harmonics
					 | 
					
						<3000MHz : None. >3000MHz :<–40dBc (typ) @ +7dBm
					 | 
				
				
					| 
						Non-Harmonic Spurii
					 | 
					
						<–50dBc >10kHz offset 10 to 3000MHz, <-44dBc >10kHz offset 3000MHz to 6000MHz
					 | 
				
				
					| 
						Output Connector
					 | 
					
						Type N
					 | 
				
				
					| 
						Sweep
					 | 
					
						Frequency and amplitude sweep
					 | 
				
				
					| 
						Step Sweep
					 | 
					
						Step frequency and/or amplitude according to a formula over a specified number of points
					 | 
				
				
					| 
						Dwell Time
					 | 
					
						Individually programmable 0.01 to 10.000sec per step
					 | 
				
				
					| 
						Max Points
					 | 
					
						1000
					 | 
				
				
					| 
						Sweep Run
					 | 
					
						Continuous or single. Sweep up or down
					 | 
				
				
					| 
						Step Spacing
					 | 
					
						Linear or logarithmic
					 | 
				
				
					| 
						Sweep Triggering
					 | 
					
						Manual, Ext. signal, timed (0.1 – 999.9sec) or via remote interface
					 | 
				
				
					| 
						Sync Signal
					 | 
					
						Output Stable) available during dwell time. Programmable as high or low
					 | 
				
				
					| 
						List Sweep
					 | 
					
						As for Step Sweep except that a user defined table of frequency, amplitude and dwell time values defines the steps. The table can be created within the instrument or downloaded via the remote interfaces
					 | 
				
				
					| 
						Max Points
					 | 
					
						1000
					 | 
				
				
					| 
						List Storage
					 | 
					
						Up to 16 Sweep Lists can be stored permanently within the instrument
					 | 
				
				
					| 
						Point Trigger
					 | 
					
						Each point in a sweep (step or list) can be subject to a trigger event rather than a dwell time. Trigger by Manual, Ext. signal or via remote interface
					 | 
				
				
					| 
						Trim
					 | 
					
						(User Level Compensation Tables)
					 | 
				
				
					| 
						Function
					 | 
					
						A table of frequency/gain pairs allows the user to modify the generator output level with respect to frequency to calibrate an entire test set up or improve the calibration of the generator alone
					 | 
				
				
					| 
						Max Points
					 | 
					
						100
					 | 
				
				
					| 
						Interfaces
					 | 
					
						Full digital remote control through the RS232, USB, LAN and GPIB interfaces
					 | 
				
				
					| 
						RS-232
					 | 
					
						9-pin D connector. Variable Baud rate 1200 and 115200 Baud
					 | 
				
				
					| 
						USB
					 | 
					
						USB 2.0 connection. Operates as a virtual COM port
					 | 
				
				
					| 
						GPIB (IEEE-488)
					 | 
					
						Conforming with IEEE488.1 and IEEE488.2
					 | 
				
				
					| 
						LAN (Ethernet)
					 | 
					
						Standard 10/100 base-T hardware connection. ICMP and TCP/IP Protocol
					 | 
				
				
					| 
						General
					 | 
					
						 
					 | 
				
				
					| 
						Size and Weight
					 | 
					
						2U (86.5mm) height; half-rack (213mm) width; 350mm long. 3.65 kg. (8 lb)
					 | 
				
				
					| 
						Power
					 | 
					
						110-240VAC ±10% 50/60Hz; 100-120VAC ±10% 400Hz; 60VA max
					 | 
				
				
					| 
						Approvals
					 | 
					
						Complies with EN 61010-1 (Safety) and EN61326 (EMC)
					 |